(3) SCSPD1
Explanation of data ……
Indicates the linear rate start speed or linear rate end speed by SRATE.
Between SCSPD1 and SCSPD2, the time constant indicates a linear rate
characteristic because the SRATE value is fixed.
Initial value ……………
Set to the following value represented by the following expression by the SLSPD
SET or SHSPD SET command.
1
SCSPD1=SLSPD+(SHSPD-SLSPD)×
3
Adjusting range …………
SLSPD≦SCSPD1≦SCSPD2
Note1: When SCSPD1<SLSPD is specified, SCSPD1=SLSPD.
When SCSPD1>SCSPD2 is specified, SCSPD1=SCSPD2.
Note2: After the SLSPD SET or SHSPD SET command is executed,
the SCSPD1 value adjusted prior to the execution is invalidated and reset to
the initial value.
When DRIVE TYPE has been changed by the SPEC INITIALIZE1 command, the SCSPD1
value is reset to the initial value.
(4) SCSPD2
Explanation of data ……
Indicates the linear rate end speed or linear rate start speed by SRATE.
Between SCSPD1 and SCSPD2, the time constant indicates a linear rate
characteristic because the SRATE value is fixed.
Initial value ……………
Set to the value represented by the following expression by the SLSPD SET or
SHSPD SET command.
2
SCSPD2=SLSPD+(SHSPD-SLSPD)×
3
Adjusting range …………
SCSPD1≦SCSPD2≦SHSPD
Note1: When SCSPD2<SCSPD1 is specified, SCSPD2=SCSPD1.
When SCSPD2>SHSPD is set, SCSPD2=SHSPD.
Note2: After the SLSPD SET or SHSPD SET command is executed,
the SCSPD2 value adjusted prior to the execution is invalidated and reset to
the initial value.
When DRIVE TYPE has been changed by the SPEC INITIALIZE1 command, the SCSPD2
value is also reset to the initial value.