- 68 -
10.INITIAL
SPECIFICATION TABLE
The initial specifications at POWER ON/RESET are shown in the following table.
The specifications related to SPEED can be switched between two types by jumpers JP1X (X axis), JP1Y (Y axis),
JP1Z (Z axis) and JP1A (A axis) on the board.
The specifications in which jumpers are provided are supplied at shipment.
Initial specification
Corresponding
Data name or specification
Jumper is provided(Note) No jumper is provided.
Command
URATE(RATE DATA TABLE No.)
No.9(100ms/1000Hz)
No.12(30ms/1000Hz)
RATE SET
DRATE(RATE DATA TABLE No.)
No.9(100ms/1000Hz)
No.12(30ms/1000Hz)
LSPD
300Hz
800Hz
LSPD SET
HSPD
3000Hz
10000Hz
HSPD SET
CSPD
300Hz
800Hz
CSPD SET
SRATE(RATE DATA TABLE No.)
No.9(100ms/1000Hz)
No.12(30ms/1000Hz)
SRATE SET
SLSPD
300Hz
800Hz
SLSPD SET
SHSPD
3000Hz
10000Hz
SHSPD SET
DRIVE TYPE
L-TYPE
LIMIT STOP TYPE
FAST STROP
SPEC INITIALIZE1
MOTOR TYPE
STEPPING
RDYINT generation pattern
Generated only upon termination of a command
accompanied by pulse output.
PULSE COUNTER operating clock
Output pulse
CNTINT generation pattern
Not generated in any case (all of COMP1 to 5)
COMP1 to 5 STOP TYPE
Not put into stop (all of COMP1 to 5)
AUTO CLEAR function
Not available
PULSE COUNTER INITIALIZE
RELOAD function
Not available
PLS COMP STOP TYPE
Fast stop
CNTINT OUTPUT TYPE
Detection of each comparator is latched and output
CNTINT LATCH TRIGGER TYPE
Level latch
DIFFERENTIAL COUNTER
Difference between MCC05v2 output pulse
operating clock
and an external clock.
DIFFERENTIAL COUNTER
Clock with 90゚phase difference
count pattern type
1 multiplication
DFLINT generation pattern
Not generated in any case (both of COMP1 to 2)
DFL COUNTER INITIALIZE
DFL COMP1,2 STOP ENABLE
Not put into stop (both of COMP1 to 5)
DFL COMP STOP TYPE
Fast stop
DFLINT OUTPUT TYPE
Detection of each comparator is latched and output
DFLINT LATCH TRIGGER TYPE
Level latch
COUNTER SELECT PORT
PULSE COUNTER
Each PORT SELECT
Current address(ADDRESS COUNTER)
0
ADDRESS INITIALIZE
OFFSET PULSE
0
OFFSET PULSE SET
LIMIT DELAY TIME
300ms
SCAN DELAY TIME
50ms
ORIGIN DELAY SET
JOG DELAY TIME
20ms
PULSE COUNTER Value
0
PULSE COUNTER PRESET
PULSE COUNTER
PULSE COUNTER
COMPARE REGISTER1 to 5 value
800000
COMPARE REGISTER1~5 SET
H
DIFFERENTIAL COUNTER value
0
DFL COUNTER PRESET
DIFFERENTIAL COUNTER
DFL COUNTER
COMPARE REGISTER1 to 2 value
0
COMPARE REGISTER1~2 SET
Note: Values with the jumpers are employed in descriptions offered in other parts of this manual.
Summary of Contents for C-875