- 40 -
Contents of the DRIVE DATA2 PORT are
DATA2 PORT
7
0
as shown to the right.
D
D
COUNT CLOCK TYPE
COUNT PATTERN TYPE
COMP1 INT ENABLE
COMP1 STOP ENABLE
Note: 2
and 2 bits must be set to 0.
3
4
Since an applied function assigned to 2 bit, it must be set to 0, too.
7
The details of each bit are shown below.
The bit is set to the underlined side at POWER ON/RESET.
(1) COUNT CLOCK TYPE (D )
0
This bit is used for selecting the operation clock for the DIFFERENTIAL COUNTER.
0: The DIFFERENTIAL COUNTER is operated with the drive pulse (XCWP and XCCWP) from
the X axis MCC05v2 and external clock from the XEA and XEB.
1: The DIFFERENTIAL COUNTER is operated only with external clock from the XEA (X axis encoder
A-phase signal) and XEB (X axis B-phase signal).
(2) COUNT PATTERN TYPE (D ,D )
1
2
This bit is used for selecting the external operation clock for the DIFFERENTIAL COUNTER.
D
D
Count pattern
Input clock type
2
1
0
0
Count by multiplying the XEA and XEB inputs by 1.
90゚ phase
0
1
Count by multiplying the XEA and XEB inputs by 2.
difference clock
1
0
Count by multiplying the XEA and XEB inputs by 4.
1
1
Count-up by XEA and count-down by XEB.
Independent clock
for each direction
Note: Output pulse from the MCC05v2 is counted down with the CW clock and counted up with CCW clock.
The following illustrates 90゜phase difference clock counting pattern.
See Section 12-11. for the detail.
EA
Count-up
EB
EA
Count-down
EB
(3) COMP1 INT ENABLE (D )
5
Determines whether or not to output the match output DFLINT of COMPARE REGISTER1.
0: DFLINT is not output.
1: DFLINT is output.
(4) COMP1 STOP TYPE (D )
6
Determines whether or not to put the pulse output into stop by the match output of COMPARE REGISTER1.
0: Not put into stop.
1: Put into stop.
Contents of the DRIVE DATA3 PORT are
DATA3 PORT
7
0
as shown to the right.
D
D
COMP2 INT ENABLE
COMP2 STOP ENABLE
Note: 2 to 2 bits must be set to 0.
2
7
(3) COMP2 INT ENABLE (D )
0
Determines whether or not to output the match output DFLINT of COMPARE REGISTER2.
0: DFLINT is not output.
1: DFLINT is output.
(4) COMP3 STOP TYPE (D )
1
Determines whether or not to put the pulse output into stop by the match output of COMPARE REGISTER2.
0: Not put into stop.
1: Put into stop.
Summary of Contents for C-875
Page 98: ... 98 2 M TYPE 3 H TYPE ...