- 47 -
6-26.SSRATE ADJUST Command
COMMAND………
63
Function : Adjusts SSRATE (time constant at a start of acceleration
H
or at an end of deceleration) required for S-RATE DRIVE.
Execution sequence
SSRATE is set in DRIVE DATA3 PORT in No. of data table.
N
BUSY=0 in
The contents of DRIVE DATA3 PORT are as follows.
STATUS1?
DATA3 PORT
7
0
Y
D
D
DATA3 PORT
WRITE
COMMAND 63
SSRATE No.
H
WRITE
SSRATE is automatically set to an approximately eightfold value of SRATE by the SRATE SET command.
When the specification is satisfied with this data, this command does not need to be executed.
For the details of automatic setting value, refer to 5-9.
Note1: After the SRATE SET command is executed, SSRATE adjusted prior to the execution becomes ineffective
and is reset to the initial value. This is also applicable to the case in which DRIVE TYPE has been
changed by the SPEC INITIALIZE1 command.
Note2: The SSRATE adjusting range is SSRATE≧SRATE. When SSRATE<SRATE, SSRATE becomes equal to SRATE.
6-27.SERATE ADJUST Command
COMMAND………
64
Function : Adjusts SERATE (at an end of acceleration or at a start of
H
deceleration) required for S-RATE DRIVE.
Execution sequence
SERATE is set in DRIVE DATA3 PORT in No. of data table.
N
BUSY=0 in
The contents of DRIVE DATA3 PORT are as follows.
STATUS1?
DATA3 PORT
7
0
Y
D
D
DATA3 PORT
WRITE
COMMAND 64
SERATE No.
H
WRITE
SERATE is automatically set to an approximately eightfold value of SRATE by the SRATE SET command.
When the specification is satisfied with this data, this command does not need to be executed.
For the details of automatic setting value, refer to 5-9.
Note1: After the SRATE SET command is executed, SERATE adjusted prior to the execution becomes ineffective
and is reset to the initial value. This is also applicable to the case in which DRIVE TYPE has been
changed by the SPEC INITIALIZE1 command.
Note2: The SERATE adjusting range is SERATE≧SRATE. When SERATE<SRATE, SERATE becomes equal to SRATE.
Summary of Contents for C-875