3.9. Explanation table
When a component is replaced you must perform the procedures indicated below -
attention: these procedures should be performed after replacement of the component and
in the order listed below.
ITEM REPLACED
PROCEDURES TO FOLLOW
CPU board (1a)
Alignment of the power board with the CPU (only
boards 2
nd
generation after March 2014)
Oven configuration procedure
Gas setup procedure
Power board (2)
Alignment of the power board with the CPU (only
boards 2
nd
generation after March 2014)
Oven configuration procedure
Combustion control PCB (3)
Oven configuration procedure
Note: After replacing one of the items listed above, at the first ignition of the oven you may
see alarms E13 and / or E20. After following the procedures listed in the table the alarms
should no longer appear.
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Page 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...