Copyright by Servizio Clienti ANGELO PO Spa
34
How to update the parameters (SW and FW alignment)
This procedure allows the user to align the parameters of the boards after replacing the
CPU board or power board. The procedure is performed after replacing the card, as
follows:
- Enter the service menu
- Select "
Update parameters
"
- Enter t
he password “
FA53
”
- Wait until the end of the procedure and follow the instructions that appear on the
display
When the procedure has finished, turn off and on the oven as written on the display.
Oven Number
: identification number of the oven
within a network of ovens
. It is used
during HACCP data download as not to create conflicts within the network and to uniquely
identify the data from each appliance.
Testing APGC:
this choice is subject to Password and is used only at the end of the test
cycle into the factory before the oven is shipped to the final customers.
Display gas
: allows visual check, during normal operation of the machine, the parameters
and the states of the gas unit. It must be repeated each time the machine is switched on.
Gas setup:
this option allows you to enter into the gas setup, the password is
SI74
.
RH% Calibration:
This selection allows you to activate the calibration procedure of the UR
probe (humidity probe). The procedure takes about 10 minutes to run. The procedure is
performed with the oven cold and finish with the oven at 230°C
. This procedure should
be performed every time you replace the UR probe or whenever you replace the
power board (2).
Clean test:
See chapter 5.3
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Page 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...