Copyright by Servizio Clienti ANGELO PO Spa
168
Alarm on
display
Problem (on
the manual)
Solution (on the
manual)
Note (on the
manual)
Note for Service
OPE
Oven door
opening or
closure request.
Open or close the oven
door. Inform the after-
sales service if this
message continues to be
displayed.
The cooking
cycle does not
start until the
door has been
opened or
closed as
required.
Check the door magnetic micro switch,
to be correctly connected to the power
PCB by wires 42 and 43. It could be
interruption or short circuit.
CLE
W01
W02
Cleaning alarm
---
---
See chapter 5.5
(cleaning warnings)
E01:CC
The cooking
chamber probe
has failed or is
not properly
connected.
(Short circuit)
Inform the after-sales
service.
The oven’s
functions are
disabled so no
cooking
cycles can be
carried out.
Check the chamber probe. The
resistance value must be about 1100
Ohm at 25°C. The probe is connected
to the terminals 44 and 45 of the power
PCB.
E01:--
The cooking
chamber probe
has failed or is
not properly
connected.
(Circuit open)
Inform the after-sales
service.
The oven’s
functions are
disabled so no
cooking
cycles can be
carried out.
Check the chamber probe. The
resistance value must be about 1100
Ohm at 25°C. The probe is connected
to the terminals 44 and 45 of the power
PCB.
E02:CC
The product
core probe has
failed.
(Short circuit)
Check the position of the
product core probe or
inform the after-sales
service if it is faulty.
Cooking
cycles with
product core
probe cannot
be carried out.
Check the core probe. The resistance
value must be about 1100 Ohm at
25°C. On the ovens level 2, the probe
is connected to the terminals 46 and 47
of the power PCB. On the ovens level
3, the multipoint core wires are
connected to terminals 74-75-76-77-78
(wires red-yellow-blue-green-black) of
the expansion PCB, and the white one
is connected to terminal 73.
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Page 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...