Copyright by Servizio Clienti ANGELO PO Spa
52
SW update - only boards 2
nd
generation (after March 2014)
The SW update from USB stick has to be done as following:
1) With the oven on in standby mode, push for at least 4 seconds the "reset" button, when
it is released the display turns off.
2) Press the "steam injection button" to enter into the SW update from USB, the first
screen displays "USb" flashing. To leave the procedure just press again "steam injection
button". If during "USb" flashing you insert a USB stick and the board recognizes it, the
flashing stops and the message "USb" is steady and also turns on the START / STOP
button in green color.
The stick
(recommended max. size 4GB)
must be formatted FAT
or FAT32 and contain a directory "AngeloPo_L1_L2" with all the necessary files
inside
).
3) Press the START / STOP in order to start the update
procedure (“-“ will run on the lower
display)
4) The update must include the CPU and the power board, no key is activated during the
update.
5) After the update the display turns off again.
How to configure the type of oven
The setup process of the oven must be done after replacing one of the following
components:
CPU board, power board, inverter, combustion control board.
It is required in order to make all the boards communicate and to select the correct
operating parameters of the oven.
Operate as follows:
o
With the oven on and in standby mode hold down (simultaneously) the keys
"convection" and "reset" for 4 seconds to enter the configuration screen.
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Page 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...