171
Alarm on
display
Problem (on
the manual)
Solution (on the
manual)
Note (on the
manual)
Note for Service
E13
Electronic circuit
board
diagnostics
tripped.
Inform the after-sales
service.
The oven’s
functions are
disabled so no
cooking
cycles can be
carried out.
Communication failure between the
boards or peripheral devices. Verify
electrical connections.
E13 = Power Board - CPU
E13a= Inverter 1
E13b= Combustion control board 1
E13c= Inverter 2
E13d= Combustion control board 2
E14
Electronic circuit
board
diagnostics
tripped.
Inform the after-sales
service.
The oven’s
functions are
disabled so no
cooking
cycles can be
carried out.
PCB temperature probe failure.
Replace the power board or the CPU
board.
E14V = CPU
E14Q = power board
E19
The humidity
probe has failed.
Inform the after-sales
service.
The oven’s
functions are
enabled so
cooking
cycles can be
carried out.
Check the connector terminals on the
probe and on the power board.
E20
Configuration
error
Inform the after-sales
service.
The oven’s
functions are
disabled so no
cooking
cycles can be
carried out.
Found inconsistencies between the
type of oven and installed boards.
Verify the installed boards (display,
power board) and devices (inverter and
combustion control), verify their proper
connection on net cables and repeat
the configuration of the oven.
E21
– E26
Washing cycle
alarms
See chapter 5.5
E27
Gas test missed
See chapter 4.5
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Page 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...