Copyright by Servizio Clienti ANGELO PO Spa
12
1.3. Instruction to reduce width
FX61, FX101
The smallest dimension (depth) of the 61-101 models is about
900mm
.
It is possible to reduce it by:
Option A - 20mm
- removing the T protection from the oven drain.
Option B - 66mm
- removing the T-protection from the oven drain, the T-pipe from the
drain and the cooling fan protection at the back.
Option C - 56mm
- disassembling the handle / lock assembly and handle.
By combining options B and C the minimum oven measurement is approximately 778mm.
FX82, FX122
The smallest dimension (depth) of models 82-122 is about
1093mm
. It is possible to
reduce it by:
Option A - 20mm -
removing the T protection from the oven drain
.
Option B - 68mm
- removing the T-protection from the oven drain, the T-pipe from the
drain and the cooling fan protection at the back.
Option C - 56mm
- disassembling the handle / lock assembly and handle.
By combining options B and C the minimum oven measurement is approximately
970mm
.
Option D
(valid only for FX82) - As follows:
- disassemble the oven body from the support (the screws to be removed are at the top of
the 4 uprights and on the inside of the base where the two support bars are).
- lift the oven body and make it pass through the narrower part.
- Reassemble the oven body on the support.
The minimum oven measurement possible is about
905mm
.
Summary of Contents for ANGELO PO COMBISTAR FX
Page 1: ...1 Rev 0 ...
Page 6: ...Copyright by Servizio Clienti ANGELO PO Spa 6 1 COMMERCIAL MODEL NUMBER ...
Page 7: ...Copyright by Servizio Clienti ANGELO PO Spa 7 FX Models table ...
Page 10: ...Copyright by Servizio Clienti ANGELO PO Spa 10 OVEN CONNECTION DIAGRAM FX 61 G3 ...
Page 19: ...Copyright by Servizio Clienti ANGELO PO Spa 19 2 4 Steam producing operation injectors code ...
Page 21: ...Copyright by Servizio Clienti ANGELO PO Spa 21 ...
Page 44: ...Copyright by Servizio Clienti ANGELO PO Spa 44 ...
Page 46: ...Copyright by Servizio Clienti ANGELO PO Spa 46 Fuses on Power Board ...
Page 61: ...Copyright by Servizio Clienti ANGELO PO Spa 61 ...
Page 67: ...Copyright by Servizio Clienti ANGELO PO Spa 67 Functional diagram gas system ...
Page 104: ...Copyright by Servizio Clienti ANGELO PO Spa 104 ...
Page 151: ...Copyright by Servizio Clienti ANGELO PO Spa 151 PICTURE 7 PICTURE 8 PICTURE 5 PICTURE 6 ...
Page 162: ...Copyright by Servizio Clienti ANGELO PO Spa 162 6 15 Roll In adjustment RX201 RX202 ...
Page 163: ...Copyright by Servizio Clienti ANGELO PO Spa 163 ...