–84–
Electrical System
•
Ice thickness probe out of adjustment
•
Ice thickness probe dirty
•
Bin switch defective
•
Premature harvest
Refrigeration System
•
Non-Manitowoc components
•
Water regulating valve dirty/defective
•
Improper refrigerant charge
•
Defective head pressure control valve (remotes)
•
Defective harvest valve
•
TXV flooding (check bulb mounting)
•
Defective fan cycling control