![Manitowoc Marine Q 1000 Service Technician'S Handbook Download Page 155](http://html.mh-extra.com/html/manitowoc/marine-q-1000/marine-q-1000_service-technicians-handbook_701044155.webp)
–145–
Q1800 Series - Self-Contained Air-Cooled
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Times in minutes
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
8.5-9.3
9.4-10.3
9.9-10.9
1-2.5
80/26.7
9.0-9.9
9.8-10.8
10.5-11.5
90/32.2
9.6-10.5
10.4-11.5
11.1-12.2
100/37.8
10.6-11.6
11.5-12.6
12.4-13.6
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
Based on average ice slab weight of 13.0 - 14.12 lb.
Regular cube derate is 7%
50/10.0
70/21.1
90/32.2
70/21.1
1880
1720
1640
80/26.7
1780
1650
1560
90/32.2
1690
1570
1480
100/37.8
1550
1440
1350
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Suction pressure drops gradually throughout the freeze cycle
50/10.0
220-280
40-20
155-190
60-80
70/21.1
220-280
40-20
160-190
65-80
80/26.7
230-290
42-20
160-190
65-80
90/32.2
260-320
44-22
185-205
70-90
100/37.8
300-360
46-24
210-225
75-100
110/43.3
320-400
48-26
215-240
80-100
Summary of Contents for Marine Q 1000
Page 1: ... Manitowoc Ice Inc P N 80 1099 9 8 03 ...
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ... 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ... 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ... 24 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ... 69 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 80: ... 70 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 114: ... 104 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 173: ... 163 SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING USING PINCH OFF TOOL ...
Page 177: ......
Page 178: ......