![Manitowoc Marine Q 1000 Service Technician'S Handbook Download Page 141](http://html.mh-extra.com/html/manitowoc/marine-q-1000/marine-q-1000_service-technicians-handbook_701044141.webp)
–131–
Q600 Series - Self-Contained Air-Cooled
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Times in minutes
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
7.1-8.4
7.8-9.2
8.6-10.1
1-2.5
80/26.7
7.8-9.2
8.6-10.1
9.5-11.2
90/32.2
8.6-10.1
9.5-11.2
10.4-12.2
100/37.8
9.5-11.2
10.6-12.5
12.0-14.0
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
Based on average ice slab weight of 4.12 - 4.75 lb.
Regular cube derate is 7%
50/10.0
70/21.1
90/32.2
70/21.1
690
640
590
80/26.7
640
590
540
90/32.2
590
540
500
100/37.8
540
490
440
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Suction pressure drops gradually throughout the freeze cycle
50/10.0
195-260
42-22
155-180
75-95
70/21.1
220-290
44-22
160-185
85-100
80/26.7
220-305
52-22
160-190
90-110
90/32.2
250-325
52-23
175-195
95-115
100/37.8
280-355
54-30
195-210
95-125
110/43.3
300-385
56-32
200-225
100-135
Summary of Contents for Marine Q 1000
Page 1: ... Manitowoc Ice Inc P N 80 1099 9 8 03 ...
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ... 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ... 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ... 24 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ... 69 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 80: ... 70 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 114: ... 104 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 173: ... 163 SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING USING PINCH OFF TOOL ...
Page 177: ......
Page 178: ......