![Manitowoc Marine Q 1000 Service Technician'S Handbook Download Page 147](http://html.mh-extra.com/html/manitowoc/marine-q-1000/marine-q-1000_service-technicians-handbook_701044147.webp)
–137–
Q1000 Series - Self-Contained Air-Cooled
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Times in minutes
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
9.9-10.6
10.6-11.4
11.3-12.2
1-2.5
80/26.7
10.2-11.0
11.2-12.0
11.9-12.8
90/32.2
10.9-11.7
11.9-12.8
12.8-13.7
100/37.8
12.1-13.0
13.2-14.1
14.2-15.2
Air Temp. Entering
Condenser °F/°C
Water Temperature °F/°C
Based on average ice slab weight of 7.75 - 8.25 lb.
Regular cube derate is 7%
50/10.0
70/21.1
90/32.2
70/21.1
980
920
870
80/26.7
950
880
830
90/32.2
900
830
780
100/37.8
820
760
710
Air Temp
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Suction pressure drops gradually throughout the freeze cycle
50/10.0
220-280
38-18
135-180
65-90
70/21.1
220-280
40-18
140-180
70-90
80/26.7
225-280
42-20
140-180
70-95
90/32.2
260-295
42-22
150-200
80-100
100/37.8
300-330
42-24
210-225
80-100
110/43.3
320-360
44-24
210-240
85-120
Summary of Contents for Marine Q 1000
Page 1: ... Manitowoc Ice Inc P N 80 1099 9 8 03 ...
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ... 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ... 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ... 24 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ... 69 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 80: ... 70 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 114: ... 104 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 173: ... 163 SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING USING PINCH OFF TOOL ...
Page 177: ......
Page 178: ......