![Manitowoc Marine Q 1000 Service Technician'S Handbook Download Page 168](http://html.mh-extra.com/html/manitowoc/marine-q-1000/marine-q-1000_service-technicians-handbook_701044168.webp)
–158–
Contamination Cleanup Chart
Symptoms/Findings
Required Cleanup
Procedure
No symptoms or suspicion
of contamination
Normal
evacuation/recharging
procedure
Moisture/Air
Contamination symptoms
•
Refrigeration system
open to atmosphere for
longer than 15 minutes
•
Refrigeration test kit
and/or acid oil test
shows contamination
•
Leak in water cooled
condenser
•
No burnout deposits in
open compressor lines
Mild contamination
cleanup procedure
Mild Compressor Burnout
symptoms
•
Oil appears clean but
smells acrid
•
Refrigeration test kit or
acid oil test shows
harmful acid content
•
No burnout deposits in
open compressor lines
Mild contamination
cleanup procedure
Severe Compressor
Burnout symptoms
•
Oil is discolored, acidic,
and smells acrid
•
Burnout deposits found
in the compressor, lines,
and other components
Severe contamination
cleanup procedure
Summary of Contents for Marine Q 1000
Page 1: ... Manitowoc Ice Inc P N 80 1099 9 8 03 ...
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ... 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ... 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ... 24 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ... 69 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 80: ... 70 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 114: ... 104 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 173: ... 163 SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING USING PINCH OFF TOOL ...
Page 177: ......
Page 178: ......