–59–
Step 2. Jumper Wire Connected
from Probe to Ground
Is Water
Flowing
into the
Water
Trough?
The
Water
Level
Light Is:
The Water
Inlet Valve
Solenoid
Coil Is:
Cause
No
On
De-energized
This is normal
operation.
Do not
change any
parts.
Yes
On
De-energized
The water
inlet valve is
causing the
problem.
Yes
Off
Energized
Proceed to
step 3.