![Manitowoc Marine Q 1000 Service Technician'S Handbook Download Page 22](http://html.mh-extra.com/html/manitowoc/marine-q-1000/marine-q-1000_service-technicians-handbook_701044022.webp)
–12–
3. Insert a large screwdriver between the bottom
spring coils of the water regulating valve. Pry
upward to open the valve.
4. Hold the valve open and blow compressed air
through the condenser until no water remains.
REMOTE ICE MACHINES
1. Move the ICE/OFF/CLEAN switch to OFF.
2. “Frontseat” (shut off) the receiver service valves.
Hang a tag on the switch as a reminder to open the
valves before restarting.
3. Perform steps 1-6 under “Self-Contained Air-
Cooled Ice Machines.”
AUCS
®
ACCESSORY
Refer to the AuCS
®
Accessory manual for
winterization of the AuCS
®
Accessory.
SV1624