–114–
LOW ON CHARGE VERIFICATION
The remote ice machine requires more refrigerant
charge at lower ambient temperatures than at higher
temperatures. A low on charge ice machine may
function properly during the day, and then malfunction
at night. Check this possibility.
If you cannot verify that the ice machine is low on
charge:
1. Add refrigerant in 2 lb. increments, but do not
exceed 6 lbs.
2. If the ice machine was low on charge, the
headmaster function and discharge pressure will
return to normal after the charge is added. Do not
let the ice machine continue to run. To assure
operation in all ambient conditions, the refrigerant
leak must be found and repaired, the liquid line
drier must be changed, and the ice machine must
be evacuated and properly recharged.
3. If the ice machine does not start to operate properly
after adding charge, replace the headmaster.
FAN CYCLE CONTROL VS. HEADMASTER
A fan cycle control cannot be used in place of a
headmaster. The fan cycle control is not capable of
bypassing the condenser coil and keeping the liquid
line temperature and pressure up.
This is very apparent when it rains or the outside
temperature drops. When it rains or the outside
temperature drops, the fan begins to cycle on and off.
At first, everything appears normal. But, as it continues
raining or getting colder, the fan cycle control can only
turn the fan off. All the refrigerant must continue to flow
through the condenser coil, being cooled by the rain or
low outside temperature.
This causes excessive sub-cooling of the refrigerant.
As a result, the liquid line temperature and pressure
are not maintained for proper operation.
Summary of Contents for Marine Q 1000
Page 1: ... Manitowoc Ice Inc P N 80 1099 9 8 03 ...
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ... 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ... 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ... 24 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ... 69 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 80: ... 70 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 114: ... 104 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 173: ... 163 SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING USING PINCH OFF TOOL ...
Page 177: ......
Page 178: ......