![Manitowoc Marine Q 1000 Service Technician'S Handbook Download Page 150](http://html.mh-extra.com/html/manitowoc/marine-q-1000/marine-q-1000_service-technicians-handbook_701044150.webp)
–140–
Q1300 Series - Self-Contained Air-Cooled
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Times in minutes
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
9.4-10.5
9.9-11.1
10.9-12.2
1-2.5
80/26.7
9.9-11.1
10.6-11.8
11.6-12.9
90/32.2
11.0-12.3
11.5-12.8
12.8-14.2
100/37.8
12.3-13.7
13.2-14.7
14.7-16.3
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
Based on average ice slab weight of 10.0 - 11.0 lb.
Regular cube derate is 7%
50/10.0
70/21.1
90/32.2
70/21.1
1320
1260
1160
80/26.7
1260
1190
1100
90/32.2
1150
1110
1010
100/37.8
1040
980
890
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Suction pressure drops gradually throughout the freeze cycle
50/10.0
220-280
40-20
140-170
65-80
70/21.1
220-280
40-20
145-170
70-80
80/26.7
220-280
42-22
150-185
70-80
90/32.2
245-300
48-26
160-190
70-85
100/37.8
275-330
50-26
160-210
70-90
110/43.3
280-360
52-28
165-225
75-100
Summary of Contents for Marine Q 1000
Page 1: ... Manitowoc Ice Inc P N 80 1099 9 8 03 ...
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ... 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ... 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ... 24 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ... 69 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 80: ... 70 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 114: ... 104 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 173: ... 163 SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING USING PINCH OFF TOOL ...
Page 177: ......
Page 178: ......