–60–
Step 3.
Allow ice machine to run. Disconnect the water
level probe from control board terminal 1F, and
connect a jumper wire from terminal 1F to any cabinet
ground.
Remember, if you are past 6 minutes from starting, the
ice machine will go into a Freeze cycle water inlet
valve safety shut-off mode, and you will be unable to
complete this test. If past 6 minutes, you must restart
this test by disconnecting the jumper wire, restarting
the ice machine (step 1), and then reinstalling the
jumper wire to terminal 1F after the compressor starts.
Step 3. Jumper Wire Connected from
Control Board Terminal 1F to Ground
Is Water
Flowing
into the
Water
Trough?
The
Water
Level
Light Is:
The Water
Inlet Valve
Solenoid
Coil Is:
Cause
No
On
De-energized
The water
level probe is
causing the
problem.
Clean or
replace the
water level
probe.
Yes
Off
Energized
The control
board is
causing the
problem.
Yes
Off
De-energized
The water fill
valve is
causing the
problem.
Summary of Contents for Marine Q 1000
Page 1: ... Manitowoc Ice Inc P N 80 1099 9 8 03 ...
Page 2: ......
Page 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 19: ... 9 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 20: ... 10 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ... 24 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 79: ... 69 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 80: ... 70 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 114: ... 104 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 173: ... 163 SV1406 FIG A PINCHING OFF TUBING FIG B RE ROUNDING TUBING USING PINCH OFF TOOL ...
Page 177: ......
Page 178: ......