–93–
3. Wait five minutes into the freeze cycle.
4. Record the temperatures below and determine the
difference between them.
5. Use this with other information gathered on the
Refrigeration System Operational Analysis Table to
determine the ice machine malfunction.
____________
Inlet Temperature
____________
Outlet
Temperature
_____________
Difference
Must be within 7° at
5 minutes into
freeze cycle