EN | 39 | ACX150/250 | Diagnostic
© MAHLE
ATTACHMENT 5 – TROUBLE SHOOTING
MALFUNCTION
POSSIBLE CAUSE
POSSIBLE SOLUTION
1. If the “SD card not
present” message is
shown during switch
on and/or during
software update.
SD card absent or not
mounted well.
1. Insert or check SD card
insertion.
2. Reprogram the recharge station.
2. During the
recovery phase there
is an evident
refrigerant leak from
the exhausted oil
container.
The leak test is
negative.
Dirt inside the Oil
discharge solenoid valve.
1. Cleaning of the solenoid valve
OUT – S.
2. Check of the gasket efficiency.
3. calibrate pressure sensor
3. During the
automatic cycle it is
not possible to inject
and recover the oil.
Oil loading cell out of
calibration or defective.
1. Calibration of the exhausted
and new oil scales.
2. Replace if needed.
4. Vacuum pump
emits disturbing
vibrations
Defective vacuum pump
Vacuum pump replacement
5. After the vacuum
phase the leak test
has a negative result.
This may occur when the
vacuum time is too short,
4-5 minutes.
When a vacuum time less than 20
minutes is set, the following
message appears:
“Less than 20 minutes of vacuum
do not guarantee the execution of
a correct procedure. Continue?”.
The solution is keeping to the 20
minutes vacuum time.
6. The gas scale
appears blocked on
a certain value.
Loading cell locking
screw not sufficiently
unscrewed.
Further unscrew the locking screw
of the cell, ensuring that it is not in
contact with the cell during use.
Summary of Contents for ACX150
Page 1: ...MAHLE ACX150 250 SERVICE MANUAL fflRHLE...
Page 3: ...EN 2 ACX150 250 Contents MAHLE 16 Diagnostic 30 16 1 Failure list 30...
Page 32: ...EN 31 ACX150 250 Diagnostic MAHLE ATTACHMENT 1 REFRIGERANT FLUID CIRCUIT ACX150 250...
Page 35: ...EN 34 ACX150 250 Diagnostic MAHLE Vacuum ACX150 250...
Page 36: ...EN 35 ACX150 250 Diagnostic MAHLE Oil injection ACX150 250...
Page 37: ...EN 36 ACX150 250 Diagnostic MAHLE Refrigerant recharge ACX150 250...
Page 83: ...DE 35 ACX150 250 Diagnose MAHLE ANHANG 1 REGELKREIS K LTEMITTEL ACX150 250...
Page 86: ...DE 38 ACX150 250 Diagnose MAHLE Vakuum ACX150 250...
Page 87: ...DE 39 ACX150 250 Diagnose MAHLE leinspritzung ACX150 250...
Page 88: ...DE 40 ACX150 250 Diagnose MAHLE Entladung K hlmittel ACX150 250...
Page 134: ...FR 34 ACX150 250 Diagnostic MAHLE ANNEXE 1 CIRCUIT DU LIQUIDE REFRIGERANT ACX150 250...
Page 137: ...FR 37 ACX150 250 Diagnostic MAHLE Vide ACX150 250...
Page 138: ...FR 38 ACX150 250 Diagnostic MAHLE Injection d huile ACX150 250...
Page 139: ...FR 39 ACX150 250 Diagnostic MAHLE R frig rant de recharge ACX150 250...
Page 150: ...FR 50 ACX150 250 Diagnostic MAHLE R FRIG RANT N EST PAS SUPPORT l analyseur...
Page 152: ...FR 52 ACX150 250 Diagnostic MAHLE...
Page 185: ...IT 33 ACX150 250 Diagnosi MAHLE ALLEGATO 1 CIRCUITO FLUIDO REFRIGERANTE ACX150 250...
Page 188: ...IT 36 ACX150 250 Diagnosi MAHLE Vuoto ACX150 250...
Page 189: ...IT 37 ACX150 250 Diagnosi MAHLE Iniezione olio ACX150 250...
Page 190: ...IT 38 ACX150 250 Diagnosi MAHLE Ricarica refrigerante ACX150 250...