EN | 27 | ACX150/250 | Electrical connections
© MAHLE
suitable PPE (personal protective
equipment) is required. For compulsory
safety provisions to be followed when
using the product, the user shall refer to
the safety data sheet of Loctite® 577
manufacturer.
For further details on the product
characteristics/performance and
application instructions, please refer to
the technical data sheet of Loctite® 577
manufacturer.
Generally the points of insertion of
Loctite® 577 only in one spot with anti-
rotation purpose are on
connection/fittings where there is not an
O-ring/seal, before to apply it clean well
the surfaces.
12
Electrical
connections
On the “ATTACHMENT 3 – ELECTRICAL
CONNECTION – LOGIC ELECTRONIC
BOARD” the electric connections
between the main components and
sensors included in the equipment and
the printed circuit boards.
On the ATTACHMENT 4 – ELECTRICAL
CONNECTION – POWER ELECTRONIC
BOARD AND POWER SUPPLY
the electric connections between the
main components/actuators on the
manifold included in the equipment and
the power board circuit.
13
Spare parts
The necessary components for ordinary
and extraordinary maintenance are made
available.
Routine maintenance includes the
replacement of components subject to
wear, such as thermal paper of the
printer, or to use, such as: charge pipes,
quick couplers and piping and solenoid
valve gaskets.
Extraordinary maintenance includes the
replacement of other components such
as, i.e.: the load cells, the vacuum pump,
the pressure sensors, the printer, the
gauges and the suction unit etc.
For spare parts list please contact the
Mahle Assistance Center.
14
Replacement
interventions
14.1
Extraordinary
maintenance list
SERVICE OPERATION DESCRIPTION
Vacuum pump replacement
Vacuum pump oil replacement
Replacement of PNEUMATIC SUCTION
UNIT, which includes
Mechanical expansion valve
Distiller receiver
Compressor
Compressor oil restore separator receiver
Heat exchangers
Cleaning and/or replacement of
refrigerant charge solenoid valve
Cleaning and/or replacement of new oil
injection solenoid valve
Cleaning and/or replacement of HP-LP
on-off solenoid valves pair
Cleaning and/or replacement of vacuum
solenoid valves pair
Cleaning and/or replacement of
exhausted oil discharge solenoid valve
Cleaning and/or replacement of non-
condensable gas discharge solenoid
valve of accumulation receiver
Summary of Contents for ACX150
Page 1: ...MAHLE ACX150 250 SERVICE MANUAL fflRHLE...
Page 3: ...EN 2 ACX150 250 Contents MAHLE 16 Diagnostic 30 16 1 Failure list 30...
Page 32: ...EN 31 ACX150 250 Diagnostic MAHLE ATTACHMENT 1 REFRIGERANT FLUID CIRCUIT ACX150 250...
Page 35: ...EN 34 ACX150 250 Diagnostic MAHLE Vacuum ACX150 250...
Page 36: ...EN 35 ACX150 250 Diagnostic MAHLE Oil injection ACX150 250...
Page 37: ...EN 36 ACX150 250 Diagnostic MAHLE Refrigerant recharge ACX150 250...
Page 83: ...DE 35 ACX150 250 Diagnose MAHLE ANHANG 1 REGELKREIS K LTEMITTEL ACX150 250...
Page 86: ...DE 38 ACX150 250 Diagnose MAHLE Vakuum ACX150 250...
Page 87: ...DE 39 ACX150 250 Diagnose MAHLE leinspritzung ACX150 250...
Page 88: ...DE 40 ACX150 250 Diagnose MAHLE Entladung K hlmittel ACX150 250...
Page 134: ...FR 34 ACX150 250 Diagnostic MAHLE ANNEXE 1 CIRCUIT DU LIQUIDE REFRIGERANT ACX150 250...
Page 137: ...FR 37 ACX150 250 Diagnostic MAHLE Vide ACX150 250...
Page 138: ...FR 38 ACX150 250 Diagnostic MAHLE Injection d huile ACX150 250...
Page 139: ...FR 39 ACX150 250 Diagnostic MAHLE R frig rant de recharge ACX150 250...
Page 150: ...FR 50 ACX150 250 Diagnostic MAHLE R FRIG RANT N EST PAS SUPPORT l analyseur...
Page 152: ...FR 52 ACX150 250 Diagnostic MAHLE...