Alarm messages are coded Axxx in the window title bar.
Alarms immediately terminate the procedure and prevent its resumption.
CODE
MESSAGE
When it can
occur
Possible
causes
Actions
A000 EEPROM
NOT
WORKING
In case of
faults in the
EEPROM
memory
EEPROM
damaged
Change the logic
electronic board
A001 EEPROM
DATA
CORRUPT
In case of
faults in the
EEPROM
memory
EEPROM
damaged
Change the logic
electronic board
A002 PRESSURE
SAFETY
SWITCH
ACTIVATED
High pressure
is over 18 bar
High pressure
(due to pressure
on vessel or
circuit to vessel
closed) on
refrigerant
circuit between
equipment’s
compressor and
internal vessel.
Verify
If internal vessel
pressure level is over
18 bar, wait for
pressure reduction
disconnect
equipment from the
mains, use safety
protection, open
equipment and make
sure the valves
between compressor
and internal vessel
are open
A003 ADC
NOT
WORKING
After turning on
the equipment
ADC fault
Replacement of logic
electronic board.
A004 FAN
NOT
WORKING
Only during R-
1234yf use
Fan not working
properly
(stopped or
fan’s rpm not
adequate)
Stop use of the
equipment
check fan
connections and
if necessary, change
fan and related
cables with a new
one
change logic
electronic board with
new one.
A009 SENSORS
ERROR
Sensors not
connected or in
short circuit
Sensors
disconnected or
damaged.
To check electrical
connections or
change with new
spare part.
A032
CIRCUIT
During
The vehicle A/C
Recover the
Summary of Contents for ACX150
Page 1: ...MAHLE ACX150 250 SERVICE MANUAL fflRHLE...
Page 3: ...EN 2 ACX150 250 Contents MAHLE 16 Diagnostic 30 16 1 Failure list 30...
Page 32: ...EN 31 ACX150 250 Diagnostic MAHLE ATTACHMENT 1 REFRIGERANT FLUID CIRCUIT ACX150 250...
Page 35: ...EN 34 ACX150 250 Diagnostic MAHLE Vacuum ACX150 250...
Page 36: ...EN 35 ACX150 250 Diagnostic MAHLE Oil injection ACX150 250...
Page 37: ...EN 36 ACX150 250 Diagnostic MAHLE Refrigerant recharge ACX150 250...
Page 83: ...DE 35 ACX150 250 Diagnose MAHLE ANHANG 1 REGELKREIS K LTEMITTEL ACX150 250...
Page 86: ...DE 38 ACX150 250 Diagnose MAHLE Vakuum ACX150 250...
Page 87: ...DE 39 ACX150 250 Diagnose MAHLE leinspritzung ACX150 250...
Page 88: ...DE 40 ACX150 250 Diagnose MAHLE Entladung K hlmittel ACX150 250...
Page 134: ...FR 34 ACX150 250 Diagnostic MAHLE ANNEXE 1 CIRCUIT DU LIQUIDE REFRIGERANT ACX150 250...
Page 137: ...FR 37 ACX150 250 Diagnostic MAHLE Vide ACX150 250...
Page 138: ...FR 38 ACX150 250 Diagnostic MAHLE Injection d huile ACX150 250...
Page 139: ...FR 39 ACX150 250 Diagnostic MAHLE R frig rant de recharge ACX150 250...
Page 150: ...FR 50 ACX150 250 Diagnostic MAHLE R FRIG RANT N EST PAS SUPPORT l analyseur...
Page 152: ...FR 52 ACX150 250 Diagnostic MAHLE...
Page 185: ...IT 33 ACX150 250 Diagnosi MAHLE ALLEGATO 1 CIRCUITO FLUIDO REFRIGERANTE ACX150 250...
Page 188: ...IT 36 ACX150 250 Diagnosi MAHLE Vuoto ACX150 250...
Page 189: ...IT 37 ACX150 250 Diagnosi MAHLE Iniezione olio ACX150 250...
Page 190: ...IT 38 ACX150 250 Diagnosi MAHLE Ricarica refrigerante ACX150 250...