MCP-601 Operator’s Manual
Magni Systems, Inc.
82
C. List of Commands and Control Codes
This section is provided for the experience software programmers only that have knowledge of the
RS232/USB interfaces using commands and queries.
You transmit commands to the MCP-601 using the enhanced American Standard Code for Information
Interchange (ASCII) character encoding.
Command Format:
•
A Return at the end of a command will send that command:
i.e., CUT:MODE VIDEO
↵
•
Chain commands together at the first level with;
i.e. CONFIG:INPUT SDI; VIDEOOUT CPNT
↵
This will set the input to SDI and the analog output to CPNT
•
Chain commands together by;
i.e. MIXLEVEL:128;: CUT:MODE MIX
This will send a 50% mix level and put the unit into mix mode
NOTES:
1.
Terminal program set to the same baud rate and handshaking as MCP-601.
2.
? Returns current settings.
3.
Command definitions in
Italics.
4.
*(Value range of commands)
Command Codes:
For the list of commands and control codes, please refer to the file MCP-601 Control Command Codes
on the supplied MagniCoder Premier MCP-601 Installation CD (Part No. 840-0301-00).
Software developer Kit (SDK)
Software developer Kit (SDK) and Command Codes are available on the optional CD ROM (Part No.
840-0316-00).