Typical Application and Genlock Settings
Table 4-2, Recommended MCP-601 applications and genlock settings
Application
Video
Input
Genlock
Source
Genlock
LED
Chroma phase of
Composite analog output
Default
Memory
location
Internal
Clock
(1)
OFF
SC/H zero phase to the internal
clock
PowerUp
None
(No input)
REF IN
(2)
ON
Burst and frame locked to
Composite REF IN
1
SDI Input
(3)
ON
Sync-lock to SDI with SC/H zero
phase
2
Scan Conversion
SDI
REF IN
(4)
ON
Burst and frame locked to
Composite REF IN
--
None
(No input)
REF IN
(5)
ON
Burst and frame locked to
Composite REF IN
1
Downstream
Keying
SDI
REF IN
(5)
ON
Burst and frame locked to
Composite REF IN
--
SDI
Selected
video input
ON
Genlock to SDI video input
10
Analog
Composite
Selected
video input
ON
Genlock to analog video input
5,6,7,8,
Analog
Component
Selected
video input
ON
Sync-lock to analog video input and
at SC/H zero phase
--
Internal Keying
and Overlay
CPST2
Selected
video input
ON
Genlock to CPST2 input
--
NOTES:
1. Video outputs are genlock to the internal clock with Composite analog video at SCH phase 0.
2. Video outputs are genlock to the REF Composite video input. Loss of the REF signal will cause the
outputs to free run.
3. Video outputs are always genlock to the selected video input, if a signal is present. Loss of input signal
will caused the outputs to genlock to the internal clock.
4. All video outputs’ timing locks to the SDI input while the phase of the Composite analog output is lock to
the REF input.
5. REF IN (Black Burst or Color Black signal). The REF IN mode is only active with the SDI input or Input
None selected. It provides the phase lock timing for the Composite analog output while the other timing is
derived from the incoming SDI video. The REF IN Black Burst signal must sync and frame locked to the
SDI 601 input.