IMPULSE•VG+ Series 3 Instruction Manual - 07/25/05
3-12
Control Circuit Terminals
The table below outlines the functions of the control circuit terminals.
Classification
Terminal
Signal Function
Description
Signal Level
Sequence
Input Signal
S1
Forward run/stop
Forward run when closed, stop when open
120 VAC ± 10%
S2
Reverse run/stop
Reverse run when closed, stop when open
S3
Speed 2
Multi-function contact inputs (H1-01 to H1-06)
S4
Speed 3
S5
Speed 4
S6
Speed 5
S7
External Fault
S8
M-Speed Gain 1
SN
Control Input Common
Analog
Input Signal
+V
+15V
Power supply output
For analog c15V power supply
+15V
(Allowable current 20
mA max.)
-V
-15V
Power supply output
For analog command -15V power supply
-15V
(Allowable current 20
mA max.)
A1
Master frequency
reference
-10 to +10V/-100% to 100%
0 to +10V/0 to 100%
-10 to +10V (20k Ohm),
0 to +10V/(20k Ohm)
A2
Multi-function analog
reference
4 to 20 mA/0 to 100%
-10 to +10V/-100% to 100%
0 to 10 V/0 to 100%
Multi-function
analog reference
(H3-09)
4 to 20mA (250 Ohm)
-10 to +10V (20k Ohm),
0 to +10V/(20k Ohm)
A3
Multi-function analog
input
-10 to +10V/-100% to +100%
0 to +10 V/0 to 100%
Auxiliary analog
input (H3-05)
-10 to +10V (20k Ohm),
0 to +10V/(20k Ohm)
AC
Common terminal for
control circuit
0V
–
E(G)
Connection to shield
sheath of signal lead
–
–
Relay
Output Signal
M0
Brake output
N.O. Contact
Multi-function output (H2-01 to H2-03)
Dry contact
Contact capacity:
250VAC, 1A or less
30VDC, 1A or less
M1
M2
N.O./N.C. Contact
M3
M4
M5
Fault annunciate
M6
MA
Fault contact output
(NO/NC contact)
Terminals MA & MC N/O; closed at major faults
Terminals MB & MC N/C open at major fault
MB
MC
Analog
Output Signal
FM
Multi-Function Analog
Output 1
0 to ± 10V
Multi-function
analog monitor
(H4-01 to H4-03)
0 to ±10V Max. ±5%
2mA or less
AC
Common
AM
Multi-Function Analog
Output 2
0 to ± 10V
Multi-function
analog monitor 2
(H4-04 to H4-06)
0 to ±10V Max. ±5%
2mA or less
Summary of Contents for IMPULSE VG+ Series 3
Page 1: ...Software 8001 X July 2005 Part Number 140 10257 Copyright 2005 Magnetek Instruction Manual...
Page 6: ...c h a p t e r 1 Introduction...
Page 7: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 1 2 This page intentionally left blank...
Page 14: ...c h a p t e r 2 Installation...
Page 15: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 2 2 This page intentionally left blank...
Page 23: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 2 10 This page intentionally left blank...
Page 24: ...c h a p t e r 3 Wiring...
Page 25: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 3 2 This page intentionally left blank...
Page 40: ...c h a p t e r 4 Programming Basic Features...
Page 41: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 4 2 This page intentionally left blank...
Page 54: ...c h a p t e r 5 Programming Advanced Features...
Page 55: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 5 2 This page intentionally left blank...
Page 149: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 5 96...
Page 150: ...Troubleshooting IMPULSE VG Series 3 c h a p t e r 6...
Page 151: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 6 2 This page intentionally left blank...
Page 170: ...A p p e n d i x A IMPULSE VG Series 3 Parameter Listing...
Page 171: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 A 2 This page intentionally left blank...
Page 183: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 A 14...