IMPULSE•VG+ Series 3 Instruction Manual – 07/25/05
5-67
Digital Outputs
The IMPULSE•VG+ Series 3 has three multi-function control outputs for indicating various
conditions. The following table lists the function selections for the multi-function contact outputs
and indicates the control modes during which each function can be enabled.
Parameter
Code
Display
Function
Reference
Page
Number
H2-01
Terminal M0-M1
Digital Output 1 Function
---
0–FF
0
Adv
H2-02
Terminal M2-M3-M4
Digital Output 2 Function
---
0–FF
0
Adv
H2-03
Terminal M5 - M6
Digital Output 3 Function
---
0–FF
78
Adv
0
Brake Release
Closed when voltage or
frequency is output
n/a
1
Zero Speed
Closed when below B2-02 or
D1-01
n/a
2
Fref/Fout Agree 1
Output when Frequency
Reference and Frequency
Output agree
5-79
3
Fref/Set Agree 1
Output when Output
Frequency Reference equals
L4-01.
5-79
4
Freq Detect 1
Closed when output frequency
is < L4-01.
5-79
5
Freq Detect 2
Closed when output frequency
is > L4-01.
5-79
6
Inverter Ready
Closed when an inverter is
not in a fault state
n/a
7
DC Bus Undervolt
Closed when DC Bus voltage
drops belowUV trip point.
n/a
8
BaseBlk N.O.
Closed when the inverter is
not outputting voltage.
n/a
9
Operator Reference
Closed when the frequency
reference is input from the
digital operator (02-01).
5-89
A
Local Operation
Closed when the RUN
command is input from the
digital operator.
5-89
B
Trq Det 1 N.O.
Output when torque > L6-02
5-82
D
DB Overheat
Closed when inverter displays
“RH” or “RR” fault.
n/a
E
Fault
Closed during a major fault.
6-3
F
Not Used
No function
10 Minor Fault
Closed during minor fault or
alarm.
6-3
11
Reset Cmd Active
Closed when a reset
command is present on the
terminals
n/a
12 Timer Output
Timer function output
5-40
13 Fref/Fout Agree 2
Closed when output frequency
= frequency reference
5-80
14 Fref/Set Agree 2
Closed when output frequency
= L4-03
5-80
Summary of Contents for IMPULSE VG+ Series 3
Page 1: ...Software 8001 X July 2005 Part Number 140 10257 Copyright 2005 Magnetek Instruction Manual...
Page 6: ...c h a p t e r 1 Introduction...
Page 7: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 1 2 This page intentionally left blank...
Page 14: ...c h a p t e r 2 Installation...
Page 15: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 2 2 This page intentionally left blank...
Page 23: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 2 10 This page intentionally left blank...
Page 24: ...c h a p t e r 3 Wiring...
Page 25: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 3 2 This page intentionally left blank...
Page 40: ...c h a p t e r 4 Programming Basic Features...
Page 41: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 4 2 This page intentionally left blank...
Page 54: ...c h a p t e r 5 Programming Advanced Features...
Page 55: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 5 2 This page intentionally left blank...
Page 149: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 5 96...
Page 150: ...Troubleshooting IMPULSE VG Series 3 c h a p t e r 6...
Page 151: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 6 2 This page intentionally left blank...
Page 170: ...A p p e n d i x A IMPULSE VG Series 3 Parameter Listing...
Page 171: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 A 2 This page intentionally left blank...
Page 183: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 A 14...