IMPULSE•VG+ Series 3 Instruction Manual – 07/25/05
5-13
Accel/Decel Time Switching Frequency
Accel/Decel times can be changed automatically without using multi-function inputs. When multi-
function contact inputs are set for Accel/Decel selection, this command has priority over automatic
change of Accel/Decel.
Parameter
Code
Display
Function
Range
Initial
Value
Access
Level
B5-05
Accel Time N Chg
Sets acceleration time at Speed Switch
frequency.
0.0–25.5 sec
2.0
Adv
B5-06
Dec Time N Chg
Sets deceleration time at Speed
Switch frequency.
0.0–25.5 sec
2.0
Adv
B5-08
Fault Stop Time
Sets deceleration time for complete
stop at external fault. See External
Response Selection page 5-89.
0.0–25.5 sec
0.5
Adv
B5-09
Acc/Dec Units
Determines acceleration and
deceleration time interval and range.
1
Adv
0
0.01sec for 0.00–2.55 sec
Note: Setting will not change if any acc/dec time is > 255 sec.
1
0.1sec for 0.0–25.5
B5-10
Acc/Dec SW Freq
Determines acceleration/deceleration
switching level
0.0–150.0Hz 60.0
Adv
B5-11
SW Freq Compare
Determines when Acceleration Time
and Deceleration Time at Speed
Switch Hz is enabled;
1
Adv
0
lower SW Freq
0: B5-05/06 is enabled, N-out
≤
B5-10
1
upper SW Freq
1: B5-05/06 is enabled, N-out
≥
B5-10
B5-12
Accel Time 3
Acceleration time when H1-01 to H1-
06 = 1B
0.0-6000.0
3.0
Adv
B5-13
Decel Time 3
Deceleration time when H1-01 to H1-
06 = 1B
0.0-6000.0
3.0
Adv
B5-14
Accel Time 4
Acceleraton time when H1-01 to H1-
06 = 1C
0.0-6000.0
3.0
Adv
B5-15
Decel Time 4
Deceleraton time when H1-01 to H1-
06 = 1C
0.0-6000.0
3.0
Adv
Summary of Contents for IMPULSE VG+ Series 3
Page 1: ...Software 8001 X July 2005 Part Number 140 10257 Copyright 2005 Magnetek Instruction Manual...
Page 6: ...c h a p t e r 1 Introduction...
Page 7: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 1 2 This page intentionally left blank...
Page 14: ...c h a p t e r 2 Installation...
Page 15: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 2 2 This page intentionally left blank...
Page 23: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 2 10 This page intentionally left blank...
Page 24: ...c h a p t e r 3 Wiring...
Page 25: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 3 2 This page intentionally left blank...
Page 40: ...c h a p t e r 4 Programming Basic Features...
Page 41: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 4 2 This page intentionally left blank...
Page 54: ...c h a p t e r 5 Programming Advanced Features...
Page 55: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 5 2 This page intentionally left blank...
Page 149: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 5 96...
Page 150: ...Troubleshooting IMPULSE VG Series 3 c h a p t e r 6...
Page 151: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 6 2 This page intentionally left blank...
Page 170: ...A p p e n d i x A IMPULSE VG Series 3 Parameter Listing...
Page 171: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 A 2 This page intentionally left blank...
Page 183: ...IMPULSE VG Series 3 Instruction Manual 07 25 05 A 14...