215009
100
Revision A
1021476
A
Figure 4.9: Cutterbars
5.
Open cutterbar doors (A). For instructions, refer to
.
1022896
A
A
Figure 4.10: Spirit Level on Cutterbar
6.
Use a spirit (bubble) level (A) to ensure the cutterbar is
level in both directions. Adjust the header accordingly.
1004033
A
B
Figure 4.11: Cutterbar Oil Inspection Plug
7.
Clean the area around plug (A). Place a 5 liter (5.2 US qts)
capacity container under plug (A).
8.
Use a 17 mm socket to remove plug (A) and O-ring (B) from
cutterbar. Oil level must be up to the inspection plug hole.
NOTE:
If additional lubricant is required, refer to Step
If additional lubricant is
NOT
required, proceed to Step
IMPORTANT:
Do
NOT
overfill the cutterbar. Overfilling can cause
overheating, damage, or failure of cutterbar components.
9.
Reinstall the inspection plug.