SRP View Tab
To further evaluate a barcode error, you may wish to see the Scan Reflectance
Profile (SRP). Select the
SRP View
tab (see above Figure). The SRP is
displayed for the selected area as determined by the blue line overlaying the
image of the barcode on the top left side of the screen.
You can look at the SRP for any part of the barcode by simply clicking on another
part of the image in the box located on the upper left corner of the
SRP View Tab
screen.
View Section
Under the View section, you can select what kind of error will be super-imposed
onto the SRP graph. Rmax and Rmin numbers are also displayed.
Options include:
Element
reflectance
Modulation (EC = Edge Contrast)
SRP View Screen showing a defect error