4.
Parameters
4-29
Parameter
Unit
Initial
Details
Applic
ation
mode
Code
Name
Minimum
Maximum
St-19
Internal
temperature
[
℃
]
0
Displays the internal temperature sensor value.
PST
Room
temperature
-40 200
St-20
Rated motor
speed
[RPM] 0
Displays the rated speed of the currently
installed motor.
PST
Rated RPM 0
10000
St-21
Maximum motor
speed
[RPM] 0
Displays the maximum speed of the currently
installed motor.
PST
Maximum RPM 0
10000
St-22
Rated motor
current
[A] 0.00
Displays the rated current of the currently
installed motor.
PST
Rated current 0.00
655.35
St-23
U phase current
offset
[mA] 0
Displays the U phase current offset.
PST
U Phase current
offset
-200 200
St-24
V phase current
offset
[mA] 0
Displays the V phase current offset.
PST
V phase current
offset
-200 200
St-25
Program version -
-
Displays the version of the currently installed
program.
(Details: Refer to “4.3.7 Software Version
Display.”)
PST
Software version -
-
St-26
FPGA Version
-
-
Displays the version of the currently installed
FPGA version.
PST
FPGA Version
-
-
St-27
Analog Torque
Command
% 0 Displays the values of the current analog
torque command
T
Analog Tq CMD -3000
3000