4.
Parameters
4-11
4.1.6
External Input Signal and Logic Definition
The following describes how to allocate input signals and how to view them.
(1)
Input Signal Allocation
XDL-L7 Drive allows for the allocation of a total of 19 input contact functions to 10 hardware
contacts.
Each of the input contact functions is located at the designated digit of parameter [P2-00],
[P2-01], [P2-02], [P2-03], or [P2-04]. Changing the value of the digit allows allocation to pins
DI1 through DIA
The default input signal allocation is as follows:
One number can be allocated to two input signals such as N (input signal): 1 (input allocation
number).
E.g.) If SVON and SPD1 are allocated to DI #01, you can use both the SVON signal and the
SPD1 signal when entering DI #01.
Caution
If you change the input contact function, Since it is an immediate effect on the drive, you need to be
careful for the operation.
Before change, recommended to be set ‘EEPROM save no use’ in DIGIT 5 of [P0-17] parameter
..
Input Signal
Input Allocation Number