4.
Parameters
4-41
4.2.6
Speed Operation Setting Parameter
For detailed information, refer to "4.4.5 Speed Operation Parameter Setting."
“**” Modification is not possible with the servo on & Power reset parameter.
Parameter
Unit
Initial
Details
Code
Name
Minimum
Maximum
P3-00
Speed command 1
[RPM]
10
Sets 1-6 speed commands based on the speed
command input contact.
SPD1
SPD2
SPD3
Speed Control
OFF OFF OFF
Analog
speed
command
ON OFF OFF
Digital
speed
command 1
OFF ON
OFF
Digital
speed
command 2
ON ON OFF
Digital
speed
command 3
OFF OFF ON
Digital
speed
command 4
ON OFF ON
Digital
speed
command 5
OFF ON ON
Digital
speed
command 6
ON ON ON
Digital
speed
command 7
(Details: Refer to “4.4.5 Speed Operation
Parameter Setting.”)
Speed command 1
-6000
6000
P3-01
Speed command 2
[RPM]
100
Speed command 2
-6000
6000
P3-02
Speed command 3
[RPM]
500
Speed command 3
-6000
6000
P3-03
Speed command 4
[RPM]
1000
Speed command 4
-6000
6000
P3-04
Speed command 5
[RPM]
1500
Speed command 5
-6000
6000
P3-05
Speed command 6
[RPM]
2000
Speed command 6
-6000
6000
P3-06
Speed command 7
[RPM]
3000
Speed command 7
-6000
6000
P3-07
Z detection operation speed
[RPM]
10
Sets Z detection operation speed.
Z search operation speed
1
300
P3-08
Speed command acceleration
time
[ms] 0
Sets acceleration time for speed commands.
(Details: Refer to “4.4.5 Speed Operation
Parameter Setting.”)
Speed command
ACC. time
0 10000
P3-09
Speed command deceleration
time
[ms] 0
Sets deceleration time for speed commands.
(Details: Refer to “4.4.5 Speed Operation
Parameter Setting.”)
Speed command DEC. time
0
10000
P3-10
Speed command S-curve
time
[ms] 10
Sets S-Curve time for speed commands.
Speed command
S-curve time
1 100
*P3-11
Speed operation pattern
-
0
Sets acceleration/deceleration type for speed
commands.
(0;Trapezoidal, 1;Sinusoidal)
(Details: Refer to “4.4.5 Speed Operation
Parameter Setting.”)
ACC.DEC. pattern
0
1
P3-12
Manual JOG operation speed
[RPM]
500
Sets operation speed for manual JOG operation
[Cn-00].
JOG operation speed
-6000
6000