5. Handling and Operation
5-6
5.2.3
Alarm Reset [Cn-02]
Reset the alarm that went off.
1.
Contact alarm reset: If you turn on ALMRST among input contacts, the alarm is reset and becomes
normal.
2.
Operation alarm reset: If you press [SET] in the alarm reset [Cn-02] parameter among operation
handling parameters, [ALrst] is displayed. If you press [SET] again, the alarm is reset and becomes
normal.
※
If the alarm keeps ringing after the reset, check and remove possible causes and then repeat
the process.
[Example of alarm reset]
Order
Loader Displays
Keys to Use
What to Do
1
Displays the speed control mode
with main power and control power
permitted.
2
Press [MODE] to move to [Cn-00].
3
Press [UP] or [DOWN] to move to
[Cn-02].
4
Press [SET] to enter alarm reset
mode.
5
Press [SET] to reset the alarm.
[done] is displayed.
6
Press [MODE] for a second to return
to [Cn-02].
※
“ ” indicates flickering.