3. Wiring Method
3-8
(XDL-L7SA020
□
~ XDL-L7SA035
□
)
A
B
C
1) Refer to the drawings above for wiring with BLF 5.08 or BLZ 7.62HP Series connector.
2) Insert wire into wire-hole when upper screw is untightened and then, use appropriate (-) shaped
screwdriver with 0.4 ~ 0.5[N.m] torque to make tight completely.
3) Cut by vibration, malfunction or fire by contact could be occurred if torque of screwing was not enough.
4) After wiring, tight completely by using hooks to both side when connectors are attached to servo drive.
5) FG screw, which is located on the bottom of servo drive, has to be M4 and put on the FG screw with
1.2[N.m] torque.
6) Malfunction of drive could be occurred if torque of screwing was not enough.
7) Recommended (-) shaped screwdriver: Weidmueller’s SD 0.6x3.5x100.
M4 : 1.2[N
·
m]
Weidmueller’s
SD 0.6x3.5x100
0.4~0.5[N
·
m]
Length of strip
7~10[
㎜
]