6. Communication Protocol
6-17
6.3.5
Speed Operation Parameter Communication
Address Table
The following table lists Modbus communication addresses for the speed operation
parameter group [P3-xx].
Communicatio
n Address
Parameter Name
Parameter
Number
Material Type
(Decimal
Number)
Input/Output Parameter Parameter
280
Digital speed command 1
P3 - 00
INT16
282
Digital speed command 2
P3 - 01
INT16
284
Digital speed command 3
P3 - 02
INT16
286
Digital speed command 4
P3 - 03
INT16
288
Digital speed command 5
P3 - 04
INT16
290
Digital speed command 6
P3 - 05
INT16
292
Digital speed command 7
P3 - 06
INT16
294
Z search operation speed setting
P3 - 07
UINT16
296
Speed command acceleration time
P3 - 08
UINT16
298
Speed command deceleration time
P3 - 09
UINT16
300
Speed command S-Curve time
P3 - 10
UINT16
302
Speed operation pattern
P3 - 11
UINT16
304
Manual JOG operation speed
P3 - 12
INT16
306
Program JOG operation speed 1
P3 - 13
INT16
308
Program JOG operation speed 2
P3 - 14
INT16
310
Program JOG operation speed 3
P3 - 15
INT16
312
Program JOG operation speed 4
P3 - 16
INT16
314
Program JOG operation time 1
P3 - 17
UINT16
316
Program JOG operation time 2
P3 - 18
UINT16
318
Program JOG operation time 3
P3 - 19
UINT16
320
Program JOG operation time 4
P3 - 20
UINT16
322
Reserved
324
Reserved
326
Reserved
328
Reserved