Printhead Tests
Mirror Motor Test
1.
Select
PRINTHEAD TESTS
from the Diagnostics Menu.
2.
Select
Mirror Motor Test
.
The panel displays
Motor Running
.
After the test completes, the panel displays either
Pass
or
Fail
.
To stop the test, Touch
Back
or press
.
Servo Laser Test
1.
Select
PRINTHEAD TESTS
from the Diagnostics Menu.
2.
Select
Servo Laser Test
.
The panel displays
Motor Running
. After the test completes, the panel displays either
Pass
or
Fail
.
To stop the test, Touch
Back
or press
.
Device Tests
Note:
These tests only appear if the flash or disk option is installed.
Dynamic
sensors
Fuser Exit
Open/Closed
Open the top access cover. Activate the fuser
exit flag. The sensor should change state.
Input
Open/Closed
Remove the paper tray 1. Activate the input
sensor flag. The sensor should change state.
Door
Open/Closed
Open the front door. The sensor should
change state.
Narrow Media
Open/Closed
Test the MP feeder tray by inserting a sheet of
paper, and pushing up to sensor. The sensor
should change state.
K Toner
Open/Closed
Remove the black toner cartridge. Shine a
flashlight on the toner level sensor. The
sensor should change state.
M Toner
Open/Closed
Remove the magenta toner cartridge. Shine a
flashlight on the toner level sensor. The
sensor should change state.
C Toner
Open/Closed
Remove the cyan toner cartridge. Shine a
flashlight on the toner level sensor. The
sensor should change state.
Y Toner
Open/Closed
Remove the yellow toner cartridge. Shine a
flashlight on the toner level sensor. The
sensor should change state.
TPS (toner patch
sensor)
Open/Closed
Open the front access door. Slip a piece of
paper between the TPS and the transfer
module. The sensor should change state.
Bubble
Open/Closed
Open the front door. Activate the fuser entry
flag. The sensor should change state.
Dynamic MPF
Open/Closed
Test by removing the MPF pick arm and
activating the paper present sensor or remove
the tray and shine a flashlight on the paper
present sensor.
Other Sensors
Bin Full Test
Open/Closed
Move the bin full sensor flag (located on the
fuser) up and down to toggle the sensor state.
Sensor type
Sensor name
Possible values
Sensor activation
Summary of Contents for CS748de
Page 13: ...Notices and safety information xiii 5026 Go Back Previous Next ...
Page 14: ...xiv Service Manual 5026 Go Back Previous Next ...
Page 20: ...xx Service Manual 5026 Go Back Previous Next ...
Page 38: ...1 18 Service Manual 5026 Go Back Previous Next ...
Page 229: ...Diagnostic aids 3 51 5026 Go Back Previous Next Theory of operation Paper path ...
Page 252: ...3 74 Service Manual 5026 Go Back Previous Next ...
Page 400: ...4 148 Service Manual 5026 Go Back Previous Next 5 Engage the gear B ...
Page 440: ...4 188 Service Manual 5026 Go Back Previous Next 9 Remove the two screws G G 18B1236 ...
Page 468: ...4 216 Service Manual 5026 Go Back Previous Next ...
Page 469: ...Connector locations 5 1 5026 Go Back Previous Next 5 Connector locations Locations ...
Page 472: ...5 4 Service Manual 5026 Go Back Previous Next ...
Page 482: ...7 8 Service Manual 5026 Go Back Previous Next Assembly 4 Right ...
Page 484: ...7 10 Service Manual 5026 Go Back Previous Next Assembly 5 Rear ...
Page 504: ...I 10 Service Manual 5026 Go Back Previous Next ...