2-70
Service Manual
5026
Go Back
Previous
Next
6
1. POR the printer.
2. Place a voltmeter between pin 8 and pin 6
(ground) on the JFUSER1 connector on
the system board.
3. Does the meter read +5 V dc?
Go to step 7.
Replace the system board.
See
“System board
removal” on page 4-163
.
7
Place a voltmeter between the fuser
autoconnect pin 8 and ground (6).
Does the meter read +5 V dc?
Go to step 8.
Replace the fuser DC
cable. See
“Fuser DC
cable removal” on
page 4-121
.
Step
Questions / actions
Yes
No
Pin 6
(ground)
Pin 8
Summary of Contents for CS748de
Page 13: ...Notices and safety information xiii 5026 Go Back Previous Next ...
Page 14: ...xiv Service Manual 5026 Go Back Previous Next ...
Page 20: ...xx Service Manual 5026 Go Back Previous Next ...
Page 38: ...1 18 Service Manual 5026 Go Back Previous Next ...
Page 229: ...Diagnostic aids 3 51 5026 Go Back Previous Next Theory of operation Paper path ...
Page 252: ...3 74 Service Manual 5026 Go Back Previous Next ...
Page 400: ...4 148 Service Manual 5026 Go Back Previous Next 5 Engage the gear B ...
Page 440: ...4 188 Service Manual 5026 Go Back Previous Next 9 Remove the two screws G G 18B1236 ...
Page 468: ...4 216 Service Manual 5026 Go Back Previous Next ...
Page 469: ...Connector locations 5 1 5026 Go Back Previous Next 5 Connector locations Locations ...
Page 472: ...5 4 Service Manual 5026 Go Back Previous Next ...
Page 482: ...7 8 Service Manual 5026 Go Back Previous Next Assembly 4 Right ...
Page 484: ...7 10 Service Manual 5026 Go Back Previous Next Assembly 5 Rear ...
Page 504: ...I 10 Service Manual 5026 Go Back Previous Next ...