2-120
Service Manual
5026
Go Back
Previous
Next
4
Remove the HVPS. See
“High-voltage
power supply (HVPS) removal” on
page 4-123
. Check for continuity between the
contacts (yellow1 and yellow2, cyan1 and
cyan2, magenta1 and magenta2, or black1
and black2) on the transfer contact assembly.
Go to step 5.
Replace the transfer
contact assembly.
Is continuity present?
5
Replace the HVPS. See
“High-voltage
power supply (HVPS) removal” on
page 4-123
.
Does the error clear?
Problem resolved.
Replace the system board.
See
“System board
removal” on page 4-163
.
Step
Questions / actions
Yes
No
yellow2
cyan2
magenta2
black2
yellow1
cyan1
magenta1
black1
Summary of Contents for CS748de
Page 13: ...Notices and safety information xiii 5026 Go Back Previous Next ...
Page 14: ...xiv Service Manual 5026 Go Back Previous Next ...
Page 20: ...xx Service Manual 5026 Go Back Previous Next ...
Page 38: ...1 18 Service Manual 5026 Go Back Previous Next ...
Page 229: ...Diagnostic aids 3 51 5026 Go Back Previous Next Theory of operation Paper path ...
Page 252: ...3 74 Service Manual 5026 Go Back Previous Next ...
Page 400: ...4 148 Service Manual 5026 Go Back Previous Next 5 Engage the gear B ...
Page 440: ...4 188 Service Manual 5026 Go Back Previous Next 9 Remove the two screws G G 18B1236 ...
Page 468: ...4 216 Service Manual 5026 Go Back Previous Next ...
Page 469: ...Connector locations 5 1 5026 Go Back Previous Next 5 Connector locations Locations ...
Page 472: ...5 4 Service Manual 5026 Go Back Previous Next ...
Page 482: ...7 8 Service Manual 5026 Go Back Previous Next Assembly 4 Right ...
Page 484: ...7 10 Service Manual 5026 Go Back Previous Next Assembly 5 Rear ...
Page 504: ...I 10 Service Manual 5026 Go Back Previous Next ...