IES-0883 User Manual
Page 113
The
switch_a(config-if)#
prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2.
Usage:
Use this command to set the switching characteristics of the Layer-2 interface to trunk.
The all parameter indicates that any VLAN ID is part of its port’s member set. The none
parameter indicates that no VLAN ID is configured on this port. The add and remove
parameters will add and remove VLAN IDs to/from the port’s member set.
Use the no parameter to remove all VLAN IDs configured on this port.
3.
Command Syntax:
switchport trunk allowed vlan all
switchport trunk allowed vlan none
switchport trunk allowed vlan add VLANID
switchport trunk allowed vlan remove VLANID
switchport trunk allowed vlan except VLANID
no switchport trunk vlan
all Allow all VLANs to transmit and receive through the Layer-2 interface.
none Allow no VLANs to transmit and receive through the Layer-2 interface.
add Add a VLAN to transmit and receive through the Layer-2 interface.
remove Remove a VLAN from transmit and receive through the Layer-2 interface.
except All VLANs, except the VLAN for which the ID is specified, are part of its ports
member set.
VLANID <2-4094> The ID of the VLAN or VLANs that will be added to, or removed from,
the Layer-2 interface. A single VLAN, VLAN range, or VLAN list can be set.
For a VLAN range, specify two VLAN numbers: lowest, then highest number in the range,
separated by a hyphen.
For a VLAN list, specify the VLAN numbers separated by commas.
4.
Example:
The following example specifies to
add
the interface fe1 (port 1) to VLANID (
2
):
switch_a(config)#interface fe1
switch_a(config-if)#switchport trunk allowed vlan add 2
switch_a(config-if)#
Port Based VLAN
Switchport portbase add/remove vlan:
1.
Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The
switch_a(config-if)#
prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
Summary of Contents for IES-0883
Page 1: ...IES 0883 6 GE 2 SFP Managed Switch 20 to 60C DIN rail User Manual v1 00 1206 ...
Page 37: ...IES 0883 User Manual Page 36 Reboot Reboot Click Reboot button to restart the switch ...
Page 38: ...IES 0883 User Manual Page 37 Logout Logout Click Logout button to logout of the switch ...
Page 152: ...IES 0883 User Manual Page 151 ...