IES-0883 User Manual
Page 125
rw read-write access mode
4.
Example:
The following example adds a user (
myuser
) using snmp v3 with read-only access mode
and without authentication:
switch_a(config)#snmp-server v3-user myuser ro noauth
switch_a(config)#
SNMPv3 Auth-MD5, SNMPv3 Auth-SHA:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Add a user using snmp v3 with read-only or read-write access mode and with MD5 or SHA
authentication. Use the no form of the command to delete this user.
3.
Command Syntax:
(no) snmp-server v3-user USERNAME (ro
|
rw) auth (md5
|
sha) AUTH_PASSWORD
USERNAME Specify a user name.
ro read-only access mode
rw read-write access mode
md5 authentication method
sha authentication method
AUTH_PASSWORD authentication password
4.
Example:
The following example adds a user (
myuser
) using snmp v3 with read-write access mode
and MD5 authentication (
mypassword
):
switch_a(config)#snmp-server v3-user myuser rw auth md5 mypassword
switch_a(config)#
SNMPv3 Priv Auth-MD5, SNMPv3 Priv Auth-SHA:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Add a user using snmp v3 with read-only or read-write access mode, MD5 or SHA
authentication, and privacy. Use the no form of the command to delete this user.
Summary of Contents for IES-0883
Page 1: ...IES 0883 6 GE 2 SFP Managed Switch 20 to 60C DIN rail User Manual v1 00 1206 ...
Page 37: ...IES 0883 User Manual Page 36 Reboot Reboot Click Reboot button to restart the switch ...
Page 38: ...IES 0883 User Manual Page 37 Logout Logout Click Logout button to logout of the switch ...
Page 152: ...IES 0883 User Manual Page 151 ...