IES-0883 User Manual
Page 141
The following example sets time zone (Canada/Yukon):
switch_a(config)#clock timezone YST9YDT
switch_a(config)#
Polling Interval:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to specify the polling interval.
3.
Command Syntax:
ntp polling-interval MINUTE
MINUTE <1-10080> The polling interval. Enter a value in the range 1 to 10080 minutes.
4.
Example:
The following example specifies the polling interval
60
minutes:
switch_a(config)#ntp polling interval 60
switch_a(config)#
Daylight Saving Mode:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to enable daylight saving.
Use
no clock summer-time
command to disable daylight saving.
3.
Command Syntax:
clock summer-time TIMEZONE weekday WEEK DAY MONTH HOUR MINUTE WEEK DAY
MONTH HOUR MINUTE OFFSET
TIMEZONE Specifies the daylight saving timezone.
WEEK <1-5> Specifies weekdays from Monday to Friday.
DAY <0-6> Specifies from Sunday to Saturday.
MONTH <1-12> Specifies from January to December.
HOUR <0-23> Specifies from 0 to 23.
MINUTE <0-59> Specifies from 0 to 59.
OFFSET <1-1440> Specifies from 1 to 1440 minutes.
clock summer-time TIMEZONE date DAY MONTH HOUR MINUTE DAY MONTH HOUR
MINUTE OFFSET
Summary of Contents for IES-0883
Page 1: ...IES 0883 6 GE 2 SFP Managed Switch 20 to 60C DIN rail User Manual v1 00 1206 ...
Page 37: ...IES 0883 User Manual Page 36 Reboot Reboot Click Reboot button to restart the switch ...
Page 38: ...IES 0883 User Manual Page 37 Logout Logout Click Logout button to logout of the switch ...
Page 152: ...IES 0883 User Manual Page 151 ...