IES-0883 User Manual
Page 6
Functional Description
•
Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for industrial
environment.
•
Manageable via SNMP, Web-based, Telnet, and RS-232 console port.
•
Supports Command Line Interface in RS-232 console.
•
Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x. Auto-negotiation:
10/100/1000Mbps, full/half-duplex. Auto MDI/MDIX.
•
1000Base-SX/LX: Multi mode or Single mode SC type, 1000Base-BX: WDM Single mode
SC type.
•
Supports 4096 MAC addresses. Provides 1M bits memory buffer.
•
Store-and-forward mechanism.
•
Full wire-speed forwarding rate.
•
Alarms for power failure by relay output.
•
Operating voltage and Max. current consumption: 1.7A @ 12VDC, 0.85A @ 24VDC.
Power consumption: 20.4W Max.
•
Power supply: Redundant DC Terminal Block power inputs and 12VDC DC JACK with
100-240VAC external power supply.
•
Field Wiring Terminal Markings: Use Copper Conductors Only, 60/75
℃
, wire range
12-24 AWG, torque value 7 lb-in.
•
-20
℃
to 60
℃
(-4
℉
to 140
℉
) operating temperature range. UL508 Industrial Control
Equipment certified Maximum Surrounding Air Temperature @ 60
℃
(140
℉
).
•
For use in Pollution Degree 2 Environment.
•
Supports DIN-Rail and Panel Mounting installation.
Console Configuration
l
Connect to the switch console:
Connect the DB9 straight cable to the RS-232 serial port of the device and the RS-232
serial port of the terminal or computer running the terminal emulation application.
Direct access to the administration console is achieved by directly connecting a
terminal or a PC equipped with a terminal-emulation program (such as HyperTerminal)
to the switch console port.
l
Configuration settings of the terminal-emulation program:
Baud rate: 115,200bps
Data bits: 8
Parity: none
Stop bit: 1
Flow control: none
l
Press the “Enter” key. The Command Line Interface (CLI) screen should appear as below:
l
Logon to Exec Mode (View Mode):
At the “switch_a login:
”
prompt just type in “root” and press <Enter> to logon to Exec
Mode (or View Mode). And the “switch_a>” prompt will show on the screen.
Summary of Contents for IES-0883
Page 1: ...IES 0883 6 GE 2 SFP Managed Switch 20 to 60C DIN rail User Manual v1 00 1206 ...
Page 37: ...IES 0883 User Manual Page 36 Reboot Reboot Click Reboot button to restart the switch ...
Page 38: ...IES 0883 User Manual Page 37 Logout Logout Click Logout button to logout of the switch ...
Page 152: ...IES 0883 User Manual Page 151 ...