IES-0883 User Manual
Page 12
Front Panel Display
Power & Port Status LEDs
The LEDs are located on the front panel, displaying status for each respective
port. Please refer to the following table for more details.
Te
rmin
al
B
lo
ck
PW1
+
12 – 32VDC
–
Power Ground
PW2
+
12 – 32VDC
–
Power Ground
Earth Ground
Relay Output
1A @ 24VDC
Relay Alarm warning signal disable for following:
3.
The relay contact closes if Power1 and Power2 are both failed but Power3 on
4.
The relay contact closes if Power3 is failed but Power1 and Power2 are both on
•
There are three power inputs can be used. Redundant power function is supported
PW3
is DC Jack type with 12VDC input