PROFIBUS
48
BCL 34
Leuze electronic
18
Control bits for standard reading operation
X
19
Control bits for reading operation with acknowledged
data communication
X
20
State of device for the standard reading operation
X
21
Barcode information 4 bytes max.
X
22
Barcode information 8 bytes max.
X
23
Barcode information 12 bytes max.
X
24
Barcode information 16 bytes max.
X
25
Barcode information 20 bytes max.
X
26
Barcode information 24 bytes max.
X
27
Barcode information 28 bytes max.
X
28-32
Reserved
33
Combines several individual decoding results into one
read result
X
34
Transmission of the reading results in the fragmented
mode
X
X
X
35
Number of reading gate activations since system start-
up
X
36
Number of the reading gate since system start-up
X
37
Number of scans per
reading gate
Number of the scans in the reading gate
X
38
Relative position of the barcode label in the scanning
beam
X
39
Reading Security (Equal
Scans)
Number of redundant pieces of information for the bar-
code
X
40
Number of scans between the first and the last time of
detecting the barcode
X
41
Number of scans with processed information
X
42
Quality of the reading result
X
43
Orientation of the barcode
X
44
Number of digits in the barcode
X
45
Barcode type
X
46
Function for device positioning
X
X
47
All parameters are set to the factory settings
X
X
48
Function for device positioning (output in %)
X
X
49
Additional parameters for the switching output
(Module 14)
X
X
50
Controls the data output on the serial interface
Module
No.
Module
Description
Para-
meter
Output
data
Input
data
Table 8.3:
Overview of the project modules