PROFIBUS
74
BCL 34
Leuze electronic
8.3.20
Fragmented Reading Result
Module 34
The module defines the transfer of fragmented reading results. To occupy few i/o-data, the
reading results may be split into several fragments with this module. The fragments can
then be transmitted one after another with a handshake.
Notice!
The modules 21 to 27 are designed to transmit data of a length of up to 28 bytes only. If you
would like to transmit longer data, this can be achieved by using Module 34.
Parameters
Input Data
Output Data
Parameter
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Fragment
length
The parameter defines the maximum length of
the barcode information per fragment.
1 … 28
0
Byte
Parameter length: 1 byte
a
Input Data
Description
Rel. addr.
Data
type
Value Range
Default
Unit
CR to
module
Fragment number
Current fragment number
0.0 … 0.3
Bitarea
0 … 15
0
–
34e
Remaining
fragments
Number of fragments which still have to be
read for a complete result.
0.4 … 0.7
Bitarea
0 … 15
0
–
34e
Fragment size
Number of digits of the fragment in the
decoding result. Always corresponds to the
configured fragment length, except for the
last fragment
1
unsign8 0 … 48
0
–
34e
Input data length: 2 bytes consistently
b
c
d
Output Data
Description
Rel.
addr.
Data
type
Value Range
Default
Unit
CR to
module
Acknowledge
Control bit indicates that the frag-
ment has been processed by the
master
0.0
Bit
0 -> 1: Data has been processed by
the master
1 -> 0: Data has been processed by
the master
0
–
Output data length: 2 bytes consistently
e