Description
14
BCL 34
Leuze electronic
4.2
Modular hoods with integrated connectors MS 34 103/MS 34 105
The modular hoods with integrated connectors are necessary accessories for connecting
a BCL 34 in a PROFIBUS system. They are used to feed through the PROFIBUS connec-
tions, set the PROFIBUS address, and supply voltage to the BCL 34.
MS 34 103
The MS 34 103 offers the following interfaces:
• PROFIBUS In (HOST/BUS IN)
• PROFIBUS Out (BUS OUT)
• Voltage supply (PWR) and 1 switching input and output each (SW IN/OUT)
Figure 4.2:
MS 34 103
MS 34 105
In addition, the MS 34 105 offers the following interfaces:
• Service interface (SERVICE)
• 1 further switching input and output each (SW IN/OUT)
Figure 4.3:
MS 34 103
Further information on the modular hoods with integrated connectors may be found in the
following chapters.