PROFIBUS
78
BCL 34
Leuze electronic
8.3.25
Reading Security (Equal Scans)
Module 39
The module defines the input data for the communication of the calculated reading secu-
rity. The value refers to the currently output barcode.
Parameters
none
Input Data
Output Data
none
8.3.26
Scans per barcode
Module 40
The module defines input data for the communication of the calculated number of scans,
which are counted from the first to the last detection of the barcode.
Parameters
none
Input Data
Output Data
none
Input Data
Description
Rel.
addr.
Data type
Value Range
Default
Unit
CR to
module
Reading
Security (Equal
Scans)
Calculated reading security for the transmitted bar-
code.
The specified value determines how often each
individual digit of the barcode must be extracted
from a scan, before it is declared as valid. Only
once this condition is fulfilled for all digits, the bar-
code decoding is acknowledged as being valid.
0 … 1
unsign16
0 … 65535
0
–
Input data length: 2 bytes consistently
a
Input Data
Description
Rel.
addr.
Data type
Value Range
Default
Unit
CR to
module
Scans per barcode
Number of scans between the first and last
detecting of the barcode
0 … 1
unsign16
0 … 65535
0
–
Input data length: 2 bytes consistently