PROFIBUS
46
BCL 34
Leuze electronic
Parameters
Table 8.1:
"Common" Parameters
Parameter length: 16 bytes
Input Data
none
Output Data
none
A maximum of 4 code types, all of them with separately adjustable numbers of digits (code
lengths), are used. These are defined in 4 tables with an identical structure. These tables
are called [T1]-[T4] in the configuration program. The standard values of the parameters
described above, which depend on the code type, can be found in the following table.
Standard values
Parameter
Description
Value Range
Default
Unit
CR to
module
Code type
Released code type;
no code means that all subsequent code
tables are also deactivated.
The valid number of digits also depends on
the code type.
0: no
code
1: 2/5
Interleaved
2: Code39
6: UPC,
UPCE
7: EAN8,
EAN13
8: Code128
9: Pharmacode
10: EAN Addendum
11: Codabar
12: Code93
–
1 … 4
a
Number-of-digits
mode
Specifies how the subsequent digit num-
bers are to be interpreted.
0: Enumeration
1: Range
dec
1 … 4
b … e
Number of
digits 1
Decodable number of digits; in the case of
a range, this number defines the lower limit
1 … 63
Number of
digits 2
Decodable number of digits; in the case of
a range, this number defines the upper
limit
1 … 63
Number of
digits 3
Decodable number of digits in the enumer-
ation mode.
1 … 63
Parameter length: 1 byte
Standard values
Parameter
2/5 Interleaved
(T1)
Code 39
(T2)
EAN8, EAN13
(T3)
Code128
(T4)
Number-of-digits mode
Enumeration
Range
Enumeration
Range
Number of digits 1
10
4
8
4
Digits 2
0
48
13
63
Number of digits 3
0
0
0
0
Table 8.2:
Code type and code length, Tables 1-4
a
b
c
d
e